تماس با ما: 88563259

personal

تاریخ: 1393/01/09

 

 

 

 

 

 

 Personal Tracker User Manual

 

 

 

1. Technical Parameters

1.1 Working Voltage3.8V DC

1.2 Battery Capacity1450 mA/H

1.3 GSM Band850/900/1800/1900MHz

1.4 GPRS:Class12,TCP/IP

1.5 GSM Antenna  50Ωlinear polarization passive PiFA antenna

1.6 GPS Frequency1575MHz 20Channels

1.7 GPS Tracking Sensitivity-159dBm

1.8 GPS Capturing Sensitivity-144dBm

1.9 GPS Locating timecold start28sOpen sky

                   Hot start2sOpen sky

1.10 GPS precision10m2D RM

1.11 GPS Antenna50Ωcircular polarization 360°active ceramic antenna

1.12 Working Temperature-20℃~+70

1.13 Working Humidity20%80%RH

1.14 Measurement80×50×12 mm

 

2Characteristics

2.1 Online web platform, the historical and current location can be checked.

2.2  E-fence function

2.3  Hijack alarm9 SOS numbers can be preset

2.4  remote voice monitoring

2.5  Low battery alarm

2.6  Inlayed 3D acceleratormoving and static state, energy smart.

2.7 Change the time interval of uploading automatically according to the speed.

 2.8 Admin checks the altitude and longitude and location information by texting.

2.9 Four LED signal indicators:  blue GSM LED, green GPS LED,  red SOS and charging LED

2.10  AGPS solutionsshorter locating timehigher precision.

 

3Appearance Diagram

3.1  Appearance Diagram

MIC

 

SIM card slot


USB connector


 

 

3.2 Charging Diagram

4. Status Indicator

4.1 Green LEDGSM status indicator

When GSM signal is normalthe green LED glistens (0.3S/2S). When uploading GPRS datathe LED glistens quickly. The LED glistens slowly when in no signal (2S/5S)

4.2 Blue LEDGPS status indicator

When GPS signal is normalthe blue LED glistens. When GPS just starts but still not locates, the LED is in constant glow. The LED is off when GPS closed.

4.3 Red LED-SOS alarm switch SOS/charging status indicator

Push SOS key for 3 seconds, the LED will be in quick glow0.3S/0.3S. The device will be in SOS status. When the device is in charge, the red LED will be glisten0.2S/2S.The LED glistens slowly in low battery0.5S/4S),and will in constant glow after charging.

5. Usage

5.1 Preparation

5.2 Product check: open the packing box and check the device’s model and accessories. If wrong model or short of accessories, please contact the seller.

5.3 SIM card selection: the device needs inserting a GSM SIM card. Please refer to the seller’s advice on choose of SIM card.

5.4 SIM card installation (as followings).

   

SIM card installation

 

Put the card into the slot and push it inside

 

 Use the tool to tip the SIM card into the card slot

Text Box:  Use the tool to tip the SIM card into the card slot

 


5.5 The device will be in working status when inserted SIM card. And the device will be power off when taking off the SIM card.

NoteThe SIM card can not be inserted in wrong way

The SIM card must be with GPRS function and enough deposit

If your SIM card requires input PIN, please close the PIN input function of your mobile phone.

 

 

 

 

 

 

 

 

 

 

 

 

 

6. User Settings

1) Administrator number set

Text command

Parameter

Sample

Admin Add

710#number#

711#number#

710#13500135000#

711#13800138000#

Admin Del

D01#

D02#

D01#

D02#

Command Description

1) admin number can control the oil and power and resume factory settings

2) Only two numbers can be admin number.

3) Change admin number must resend the command.

Command Feedback

Successful SettingAdd admin account 1 OK!

 

2) View administrator number

Text command

Parameter

Sample

View

901#

901#

Command Description

This directive is used to view Device Manager number.

 

Command Feedback

Successful SettingAdmin1:

                   Admin2:

 

3)Authorized number set

Text command

Parameter

Sample

Authorized Add

101# number #

102# number #

103# number #

1101#13800138000#

2102#12345678912#

3103#12345678912#

Authorized Del

D11#

D12#

D13#

D11#

D12#

D13#

Command Description

1) Authorization number for SMS control oil.

2) only three numbers to set the authorization number

3) change the authorization number needs to delete the previous number

 

Command Feedback

Successful SettingAdd Authorization account 1 OK!

 

4) View authorized number

Text command

Parameter

Sample

View authorized

C10#

C10# 

Command Description

This directive is used to view the equipment authorization number

Command Feedback

Successful Setting

Authorization 1

Authorization 2

Authorization 3

 

5)APN

Text command

Parameter

Sample

APN Setting

802#username#password

1802#intenet#123#123#

 

Command Description

APN differs according to the local telecom operators.

For exampleAPN request passwordplease refer to Sample1and Sample2 for no password.

Command Feedback

Successful SettingSET APN OK

 

6)SERVER

Text command

Parameter

Sample

SERVER Parameter

803#SERVER # port#

803#222.217.240.243#8011#

Command Description

Change the IP and port when move to a new server

port10~65535

1 is domain and 0 is IP

Command Feedback

Successful Settingset IP OK!

 

7) View SERVER

Text command

Parameter

Sample

CIP Parameter

CIP#

CIP#

Command Description

This directive is used to set the IP address and server platform port

Command Feedback

IP222.217.240.243   PORT8011#

 

8)VIBRATION

Text command

Parameter

Sample

VIBRATION Parameter

761#2#,alarming way#

 

1)761#2#3#

Close VIBRATION

765#

765#

Command Description

the sensitivity  value of the vibration is from 1 to 51is the most sensitive and o is close. Alarming ways: 1, calling 2, texting, 3 calling and texting.

Must set the center number and receiving number.

Command Feedback

set vibration alarm levelOK!

 

9) FACTORY

Text command

Parameter

Sample

FACTORY Parameter

940#

1)940#

Command Description

Restore the factory setting

Only center number can initial this function

Factory setting will recover to the original setting

Command Feedback

Successful SettingFACTORY OK

 

10) Upload frequency

Text command

Parameter

Sample

TIMEER Parameter setting

730#uploading interval#

730#30#

Command Description

Time scope 30~180seconds 

30~180,means time intervalthe default value is 60seconds

Command Feedback

Successful SettingSet upload time, ok!

 

 

11) Low power alarm switch settings

Text command

Parameter

Sample

STATIC

750#shapl#

750#1#

750#0#

Command Description

This command is used to open or close the Low battery alert administrators when the function is enabled by default state.

 

Command Feedback

Successful SettingSet low power Switch ok!

 

12) Electronic fence set

Text command

Parameter

Sample

STATIC

FNECE#Latitude #Longitude #Radius#

FENCE#22.530530#114.02223 #5#

 

Command Description

This command is used to open or close the Low battery alert administrators when the function is enabled by default state.

 

Command Feedback

Successful SettingVersion information  IMEI

 

 

13)STATIC 

Text command

Parameter

Sample

STATIC

731#time interval#

731#5#

Command Description

Time scope1~60 minutesThe device has3D transmission and the default time interval are 5 minutes.

Command Feedback

Successful SettingSet static upload time ok!

 

14) Close Upload

Text command

Parameter

Sample

command

732#

732#

Command Description

Close Upload

Command Feedback

Successful SettingClose upload GPRS information ok!

Resume upload

MUP# uploading interval#

 

15)WHERE

Text command

Parameter

Sample

WHERE

988#

988#

Command Description

Check the longitude and altitude  and other information of the device

Command Feedback

Reply with longitude and altitude, speed and IMEL.

 

16)URL

Text command

Parameter

Sample

WHERE

666#

666#

Command Description

Check the location link of Google map

Command Feedback

<Datetime:12-07-05 13:21:30>

http://maps.google.com/maps?q=N22.540885,E113.95265

 

17)GMT

Text command

Parameter

Sample

GMT

801# location time #

801#E8#

Command Description

The default time zone is Beijing time. If time zone need revised, please operate according to the above command.

Command Feedback

Successful SettingSet time zone ok!

 

18)RESET

Text command

Parameter

Sample

RESET

930#

930#

Command Description

Reset the device

Command Feedback

Successful SettingReset system, ok!

 

19)LANG

Text command

Parameter

Sample

LANG Parameter

920#1#

1) 920#1#   Chinese

2) 920#2#    English

Command Description

When check the location, it will reply the Chinese location in Chinese language setting; while reply the URL link when in English language setting.

Command Feedback

Successful SettingSET LANG OK

 

7. Check the Location by Texting

7.1 Check the longitude and latitude by texting.

       Admin number or family mobile phone number can text to the device number and the device will open he GPS and uploading the longitude and latitude, time, speed and direction data. If the locating fails because of   environment, the device will send the last GPS location information.

7.2Call the device number to check the longitude and latitude

       Admin number or family mobile phone number can call the device number and hang up after connecting and the device will open he GPS and uploading the longitude and latitude, time, speed and direction data. If the locating fails because of   environment, the device will send the last GPS location information.

7.3 Check the location by texting.

       Admin number or family mobile phone number can text to the device’s number and the device will text back the current location information.

 

9SOS

9.1 Users press SOS key for over 3 seconds and SOS LED will glisten quickly0.3S/0.3S. The device will open the GPS and uploading the location data every 15 seconds until the SOS alarm is closed. You can close the SOS alarm by texting or online platform.

9.2 Meantime, the device will call SOS mobile phone numberadmin number, family mobile phone number until there is person answering it(the call will be recorded  and saved on the platform).

9.3 The monitoring center will open a popup window of alarm. The monitoring center can close the popup window after dealing with the alarm. The system will send a command to remove the alarm and the device will close the SOS alarm after receiving the command.

 

10. Trouble shooting

 The device is not online or offline on the web platform.

10.1 First, please check the three LED working state. If possible, you can call the devices number to check.

 

10.2 if not connectedthe device maybe out of signal. Please check the SIM card working state or go to the open sky to check.

 

10.3 If reminding the device SIM card is out of deposit, please make deposit by the telecom operator.

10.4 If connected and the device’s SIM card with enough deposit, please check with the operator that the status of the SIM card’s GPRS function.

10.5 The device power off when calling it.

10.6 Please the offline areaindividual offline or group offlinein order to check the network of the operator.

10.7 When the receiving of GSM signal is abnormal, please check the SIM card installation; or the location is out of GSM signal (like in basement).

10.8 The green GSM LED does not glow after inserting the SIM card; please check the power of the device by charging it.

نسخه اصلی مقاله: personal